• Serving Security Industry with
  • Thermal Cameras
    VP190-B-A2
    Superior Thermal Security Cameras
    Fixed Cameras
    VP190-B-A2
    Superior Thermal Security Cameras
  • Fixed Minidome Cameras
    V6812-T0
    HD 1MP IP Minidome Camera
    PTZ Dome Cameras
    VH131-A220-B160
    Megapixel IR PTZ Dome Camera

Products

VP194-B

Serving Security Industry with Technology and Dedication

Specialized Products

VP194-B Series dual channel thermal/CCD camera is a powerful around the clock, night and day multisensor observation system developed for security applications. It allows long range observation and detection using state of the art thermal imaging and CCD technology.

VP194-B Series dual channel thermal/CCD camera features a 1/4” Color CCD camera for day time operation, and a choice of high performance thermal camera using either a Dual Field of View (45/135mm) or lens or Continuous Zoom (15-100mm) lens for night operation.

VP194-B Series dual channel thermal/CCD camera is designed and constructed to withstand the harshest environmental conditions, including rain, direct sunlight, humidity and dust.

Additionally, it has the option of adding innovative Fire Detection module that allows for Fire Detection and High Risk of Fire (Hot Spot) detection at ranges up to 6km.

  • Features
  • Order Info
  • Specifications
  • Download
  • Major components : CCD camera/lens, thermal camera/lens, pan/tilt positioner
  • Applications: Perimeter security, public safety, nuclear and electric power plants, transportation, critical infrastructure and petrochemical
  • Thermal camera : The VP194-B thermal camera is available in 17µ 640 x 480 resolution
  • Day CCD camera : VP194-B includes a 1/4” color CCD camera for daytime threat detection and assessment. The imager is a high sensitivity, high zoom magnification visible camera providing color video for daytime operation
  • Pan/tilt positioner : The variable speed Pan/Tilt unit provides continuous 360° rotation of the cameras at up to 50°/sec (pan/tilt)

ModelCCD Camera/LensThermal Lens Thermal EngineVideo Type Heat & Fire Detection
VP194-B135D17V-PAP013.4-122.4mm
Continuous Zoom
45-135mm
Dual FOV
17µ 640 x 80PAL/
VP194-B100Z17V-PAP013.4-122.4mm
Continuous Zoom
15-100mm
Continuous Zoom
17µ 640 x 480PAL/
VP194-B135D17V-PAP303.4-122.4mm
Continuous Zoom
45-135mm
Dual FOV
17µ 640 x 480PALAvailable
Technical Specifications
Certifications and Approval
Product Certifications CE, FCC, IP66
Communication
RS-422/RS-485 Serial or TCP/IP
Protocol
Pelco D
Default Baud Rate 9600
Day CCD Camera
Imager Type 1/4” CCD
Focal Length 3.4 - 122.4mm (36x)
Resolution 752 x 582
S/N Ratio <50dB
Environmental
Storage Temperature -40°C to +71°C
-40° F to +160° F
Operating Temperature -40°C to +60°C
-40° F to +140° F
Humidity +40°C , 93% RH
Environmental Rating IP66
Fire Detection Specifications
Detection Algorithms Flame Detection, High Risk of Fire Ditection
Alarm Types Video Overlay, Serial Commnucation
Detection Specifications Up to 5 fires detected simultaneously, x/y pixel fire coordinates transmitted via comm.
Control Features Alarm Temperature Threshold, Up to 5 regions of non-interest, site calibration
Lens Specifications
Dual Field of View: 45/135mm – Field of View
Wide (45 mm) 14.3° (H) x 10.7° (V)
Narrow (135 mm) 4.6° (H) x 3.5° (V)
Continuous Zoom: 15~100mm – Field of View
Wide (15 mm) 42.2° (H) x 31.7° (V)
Narrow (100 mm) 6.2° (H) x 4.7° (V)
Mechanical Parameters
Weight 45/135mm lens: 15.1 kg (33.3 lbs)
15-100mm lens: 15.2 kg (33.5 lbs)
Dimensions 269mm (h) x 542mm (w) x 237mm (d)
10.59” (h) x 21.34” (w) x 9.33” (d)
Optional LRF Specifications
Maximum Range 6000m
Specified Range (NATO Target) 2800m
Minimum Range 5m
RangeAccuracy @<1500m +/- 3m
RangeAccuracy @>1500m +/- 5m
Laser Safety Rating Class 1
Nominal Wavelength 1550nm
Optional TCP/IP Specifications
Compression H.264, MJPEG
Frame Rate 1 - 30 fps
Dual Streaming 2 x Full Frame Rate @ D1
Output Data Rate 56Kb/s to 6Mb/s
Standards ONVIF Profile S
Pan/Tilt Unit
Pan/Tilt Speed 0.1-50° per second
Pan Range 360° continuous
Tilt Range -90° to +90°
Position Accuracy +/- 1.5 or 2.5 mRad
Power Requirements
Power Input 18-28VDC
Power Consumption 30w typical (static, no heaters)
350w max (moving, with heaters)
Thermal Camera
Imager Type Uncooled Microbolometer
Spectral Band 7.5-14μ
Pixel Size / Resolution 17μ / 640 x 480
Digital Zoom 12X
NETD <50° mK
Focus Control Motorized, Autofocus on Demand
Control Operation Polarity, NUC, Image flip, Manual gain/level, Optical & Digital Zoom, Autofocus on Demand
Video Format
Dual Channel (Thermal/CCD) - 2 BNC’s RS-170/CCIR, 1.0V p-p, 75ohm